Wiring (continued )

For GW unit – Manifold valve – Input unit manifold configuration

Two communication connectors in SI unit and one communication connector in Input
unit are installed respectively.
To the communication connector ( C2 ) or ( 1 ) of SI unit, connect the branch cable with
M12 connector from GW. To the communication connector ( C1 ) or ( 0 ), connect the
branch cable with M12 connector from Input unit.
To the communication connector of Input unit, connect the branch cable with M12
connector from SI unit.

GW unit

Manifold valve with SI unit
( for SV/VQC series )

Connector ( C1 ) / ( 0 )

Branch cable
with M12 connector

Connector ( C2 ) / ( 1 )

Input unit manifold

Manifold valve with SI unit
( for SV/VQC series )

Terminal plug

NOTE
When no Input unit is connected
to the connector ( C1 ) or ( 0 ) of
SI unit, mount a terminal plug on
the connector.

For GW unit – Input unit manifold configuration

To the communication connector of Input unit, connect the branch cable with M12
connector from GW unit.

Branch cable
with M12 connector

GW unit

Input unit manifold

Type, pin layout and connection diagram of the branch cable with M12 connector ( EX500-AC

-

)

M12

M12

48

16

52

L

M12

31.3

L

32.3

Straight Connector Type

M12

31.3

28.3

Angle Connector Type

EX500-AC

-SSPS

EX500-AC -SAPA

L = 300, 500, 1000, 3000, 5000 ( mm )

14.9

6

6