Sun Microsystems Sun Fire V880 User Manual
Page 108
Maintenance
108
Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting
May 2006
23. Enter the following commands:
setenv auto-boot? false
reset-all
The system reboots to the ok prompt.
24. Enter:
probe-scsi
This verifies that the system recognizes all of the disk devices, including the newly
installed ones. A message that is similar to the following example is displayed:
The devices listed depends on the number of disks that are installed in the system.
25. Enter the following commands:
CAUTION:
!
CAUTION:
If you fail to enter these commands, any reboots that you do in the future will stop
at the boot prompt instead of proceeding through the normal boot-up process.
setenv auto-boot? true
boot -r
The system reboots.
26. Log in as root.
27. Continue with
LiD HA LUN
--- Port WWN ---
-----Disk description -----
0
0
0
21000004cf72f08f
SEAGATE ST373405FSUN3660438
1
1
0
21000004cf721553
SEAGATE ST373405FSUN3660438
6
6
0
508002000016b5b1
SUNW
SUNWGS INT FCBPL9224
3
3
0
21000004cf72114b
SEAGATE ST373405FSUN3660438
4
4
0
21000004cf7211ae
SEAGATE ST373405FSUN3660438