Maintenance and Service

11.1 Removing and Installing Hardware Components

SIMATIC IPC427C
Operating Instructions, 04/2009, A5E02414743-01

71

11.1.4

Replace the backup battery

To be noted before you replace the battery

Note
The service life of a backup battery is approximately 5 - 8 years, depending on the operating

conditions.

CAUTION

Risk of damage!
The lithium battery may only be replaced with an identical battery or with a type

recommended by the manufacturer (Order No.: A5E00331143).

Disposal

CAUTION

Depleted batteries must be disposed of in accordance with local regulations.

Preparation

Note
The configuration data and contents of the SRAM in the device are buffered for at least

30 seconds.

1. Write down the current settings of the BIOS setup or save the settings as a user profile in

the Exit menu (Page 131) of the BIOS setup.

A list in which you can note this information is available in the BIOS description.

2. Disconnect the device from the power supply.

Tool

You will need a TORX T8 screwdriver to open the battery compartment.