Installing/mounting
5
5.1
Permitted mounting positions
NOTICE
The device is approved for operation in closed rooms only.
Ensure that there is a minimum clearance to the other components or the walls of a
housing:
•
Below at least 100 mm
•
Above at least 50 mm
Horizontal (preferred position)
Permitted temperatures
Operation with hard disk:
•
with up to 3 expansion modules
(max. load 9 W): +5 to +40°C
Operation with CompactFlash card and/or SSD drive:
•
with up to 3 expansion modules
(max. load 9 W): 0 to +45°C
•
with up to 3 expansion modules
(max. load 9 W) in RAL: 0 to +50°C
Operation with Compact Flash cards:
•
without expansion modules in RAL: 0 to +55°C
Vertical
(power supply at the top)
Operation with hard disk:
•
with up to 3 expansion modules
(max. load 9 W): +5 to +40°C
With installed Compact Flash card:
•
without expansion modules: 0 to +45°C
Operation with CompactFlash card and/or SSD drive:
•
with up to 3 expansion modules
(max. load 9 W) in RAL: 0 to +45°C
Operation with Compact Flash cards:
•
with up to 3 expansion modules
(max. load 9 W) in RAL: 0 to +50°C
Notes:
When mounted on a DIN rail, the device should be secured
to prevent shifting (e.g. with a DIN rail ground terminal).