Siemens Simatic Industrial PC IPC427C User Manual
Page 31
Installing/mounting
5.5 Mounting with mounting brackets
SIMATIC IPC427C
Operating Instructions, 04/2009, A5E02414743-01
31
Mounting/demounting the device
The dimensions of the device with mounting brackets are listed under Dimension drawings of
the device with mounting brackets (Page 99).
Mounting examples
Material
Bore diameter
Mounting
Concrete
8 mm diameter
60 mm depth
Dowel: 8 mm diameter
50 mm length
Screws: 4 mm diameter
50 mm length
Plasterboard
(min. 13 mm thick)
14 mm diameter
Gravity toggle: 4 mm diameter
50 mm length
Metal
(min. 2 mm thick)
5 mm diameter
Metal screws M 4: 4 mm diameter
15 mm length
WARNING
Ensure that the wall or ceiling can hold four times the total weight of the device (including