Set Sensor Type
Command Structure
a
=
0
Disable Sensor
1
Reflective (Eye-Mark ) Sensing
2
Transmissive (Label Gap or Notch) Sensing
Example:
Placement:
This command should be sendt in a separate data
stream.
Default:
Command Function
To select the top-of-label sensing method.
Input to Printer
Printer Output
Theres is no printer output as a result of this command.
Special Notes
1. The reflective Eye-Mark must be a minimum of .125" wide and at
least 1.0" long. It should be parallel to the platen and centered on
the underneath side of the label
2. The transmissive gap must be a minimum of 0.125" wide.
3. See “Sensing” on page 8 for more information on label indexing.