Command – Seiko FB-900 User Manual
Page 212

●
Command
Control code
Corresponding setup function
Code
9-12
— 9. Software setup functions —
Hexadecimal
HD + ] + n + n
(1B,7C,60,03,00,5D,
(38) Bar code type
(Setup Function #41)
6E,n)H
n=0H
INDSTRAL-2.5
7H
CODE128
1H
INTRLVD-25
8H
EAN-8
2H
MATRIX-25
9H
EAN-13
3H
CODABAR
AH
UPC-A
4H
CODE11
BH
UPC-E
5H
CODE39
CH
POSTNET
6H
CODE93
DH
ELENENT
HD + ] + x + n
(1B,7C,60,03,00,5D,
(39) Bar code size
(Setup Function #42)
78,n)H
n= 0
1
1
1.5
2
2
3
2.5
HD + ] + X + n
(1B,7C,60,03,00,5D,
(40) Enlarged character size
(Setup Function #43)
58,n)H
n= 0
1
1
2
2
4
3
8
4
12
5
16
6
24
7
32
HD + A + n
(1B,7C,60,02,00,41,n)H
(41) Software setup
(Setup Function #44)
n=0
Valid
1
Ignored 1
2
Ignored 2
The setup command cannot change the ignored setting to
the valid setting. The command becomes valid after the setup
command mode is quit.
See page 3-37.
See page 3-39.
See page 3-39.
See page 3-40.