96257
Sun Confidential: Internal Only
A-65
Revision A
Sample IOCP Gen for FICON Configuration
■
Sample IOCP Gen for FICON Configuration
Figure A-7. Sample IOCP Gen for FICON Configuration
>> NOTE: The example below shows an IOCP gen for a single MVS host connected to a VSM5 through
FICON directors.
ESCD4C CHPID PATH=(20,70), TYPE=FC, SWITCH=4C
ESCD4C CHPID PATH=(21,71), TYPE=FC, SWITCH=4D
ESCD4C CHPID PATH=(30,80), TYPE=FC, SWITCH=4E
ESCD4C CHPID PATH=(31,81), TYPE=FC, SWITCH=4F
CU1 CNTLUNIT CUNUMBER=001
PATH=(20,21,30,31,70,71,80,81),
LINK=(D0,D4,D0,D4,D4,D0,D4,D0),
UNIT=3490,CUADD=0,
UNITADD=((00,16))
STRING1 IODEVICE ADDRESS=(0500,16),
CUNUMBER=(001),
UNIT=3490,
UNITADD=00,STADET=Y
CU2 CNTLUNIT CUNUMBER=002
PATH=(20,21,30,31,70,71,80,81),
LINK=(D0,D4,D0,D4,D4,D0,D4,D0),
UNIT=3490,CUADD=1,
UNITADD=((00,16))
STRING2 IODEVICE ADDRESS=(0510,16),
CUNUMBER=(002),
UNIT=3490,
UNITADD=00,STADET=Y
.
.
.
CU15 CNTLUNIT CUNUMBER=015
PATH=(20,21,30,31,70,71,80,81),
LINK=(D0,D4,D0,D4,D4,D0,D4,D0),
UNIT=3490,CUADD=E,
UNITADD=((00,16))
STRING15 IODEVICE ADDRESS=(05E0,16),
CUNUMBER=(015),
UNIT=3490,
UNITADD=00,STADET=Y
CU16 CNTLUNIT CUNUMBER=016
PATH=(20,21,30,31,70,71,80,81),
LINK=(D0,D4,D0,D4,D4,D0,D4,D0),
UNIT=3490,CUADD=F,
UNITADD=((00,16))
STRING16 IODEVICE ADDRESS=(05F0,16),
CUNUMBER=(016),
UNIT=3490,
UNITADD=00,STADET=Y