John Deere SURFACE WATER PRO OMPFP11362 User Manual
Page 21
![background image](/manuals/132815/21/background.png)
Machine and Implement Setup
JS56696,00009D8 1917MAY113/3
Enter the correct receiver height above the ground:
Dimension D—fully raise the implement and measure
from the ground to the middle of the receiver (inches).
Dimension C—measure from the middle of the receiver to
the cutting edge.
IMPORTANT: Always measure to the exact same
place on the receiver when measuring.
Enter 0 for the For and Aft dimension for the implement
receiver if the receiver is mounted over the cutting
edge—this space is reserved for future enhancement.
For optimized performance make the Hours On After
Shutdown the same value as on the machine receiver
(24 is recommended).
NOTE: When performing a TCM calibration on the
implement receiver, the wheels of the main frame,
to which the implement receiver is mounted,
need to be in the same location after turning
implement around so the righthand wheels are
in the same place as where the lefthand wheels
were. A smooth level surface is recommended
while performing a TCM calibration.
PC13406
—UN—20APR1
1
StarFire 3000 Receiver
Perform a TCM calibration each time the receiver
is moved to a different implement or vehicle.
The implement TCM is used for determining
vertical position of the blade.
For more information refer to your StarFire 3000 operators
manual.
1513
061611
PN=21