procedures to help you solve ServeRAID problems when servicing the computer. A
complete list of error codes is in Table 12 on page 73.

EF 10 Default ISPR. No ISPR error present.

9ZXX thru BZXX

SCSI bus error caused either by cables, termination, defective drives, and
so on.

1. Isolate the error between SCSI subsystem and controller by

disconnecting all SCSI cables from suspect card, and reboot.

CAUTION:
Do not press F5. Doing so changes the configuration.
If an ISPR error is still present, take the following actions until the error
is no longer present:
a. Reseat the controller
b. Replace the controller

Note: If the controller detects a configuration change, do not choose

Save Changes. Instead, press F10 to bypass any options to this
effect.

2. If the ISPR error is EF10 after disconnecting cables:

a. Confirm that the identified channel(s) is the cause of the error by

verifying that the error presents itself only when the offending
channel is reconnected.

b. Check termination of identified channel.
c. Check for proper backplane jumper configuration.
d. Check for proper cabling configuration in systems that use DASD

status cables. Reconnect all cables that you disconnected at the
beginning of this procedure.

e. Replace SCSI cable.
f. Replace SCSI backplane.

FFFF (or other code not listed)

1. Isolate between SCSI Subsystem and controller by disconnecting all

SCSI cables attached to the suspect card, and reboot.

CAUTION:
CAUTION: Do not press F5. Doing so changes the configuration.
If ISPR code is EF10 after disconnecting cables, follow the steps below
until the error is eliminated:
a. Identify which channel is causing the error by reconnecting cables

one at a time and rebooting until the error returns.

b. Disconnect one drive at a time attached to identified channel and

reboot each time to determine which drive is causing the problem.

c. Replace SCSI cable attached to the identified channel.
d. Replace backplane attached to the identified channel

2. If the original ISPR code is still present after disconnecting all SCSI

cables and rebooting, take the following actions until the error is no
longer present:
a. Reseat the controller
b. Replace the controller

ServeRAID-4x problems and actions

Table 12 on page 73 lists problems and corrective actions associated with the
adapter. The table helps you determine which adapters may need to be replaced at
the conclusion of troubleshooting procedures.