Table 4. Descriptions of light-path diagnostics LEDs

LED

Meaning

PS1

Power supply 1 failure

PS2

Power supply 2 failure

PS3

Power supply 3 failure

NON

Non-redundant power

OVER

The system has exceeded the power capabilities of the installed power supplies

NMI

Non-maskable-interrupt occurred

TEMP

System temperature exceeded maximum rating

FAN

A fan failed or is operating slowly

MEM

Memory failure. One or more memory DIMMs have failed

CPU

Microprocessor failure. One or both microprocessors have failed

PCI A

Error on PCI channel A or system board. Note: PCI bus A is often referred to as PCI bus 0

PCI B

Error on PCI channel B or system board. Note: PCI bus B is often referred to as PCI bus 1

PCI C

Error on PCI channel C or system board. Note: PCI bus C is often referred to as PCI bus 2

VRM

VRM Error on voltage regulator module or on integrated voltage regulator

DASD

A hot-swap disk drive, backplane, or other part of SCSI channel A has failed

SP

Integrated System Management Processor detected an error

Remind button: You can use the remind button to place the front panel
system-error light into a remind mode. By pressing the button, you acknowledge the
failure but indicate that you will not take immediate action. If a new error occurs, the
LED will be on again.

In the remind mode, the system-error LED flashes every 2 seconds. The
system-error LED remains in remind mode until one of the following situations
occurs:

1. All known problems are resolved

2. The system is restarted

3. A new problem occurs

You can use the remind button to delay maintenance. Also, resetting the
system-error LED enables the LED to react to another error. If the LED is still
blinking from the first error, it will mask additional errors.

Chapter 7. Troubleshooting