IBM 201 User Manual
Page 107
Table 17. POST error messages (continued)
Error
code/Symptom
Meaning
FRU/action
1600
The Service Processor is not
functioning
1. Ensure that a jumper is not installed on J-51
2. Remove the AC power to the system, wait 20 seconds
and then reconnect the AC power. Wait 30 seconds; then,
power-on the appliance.
3. System board
4. Processor/PCI board
1601
The system is able to
communicate to the Service
Processor, but the Service
Processor failed to respond
at the start of POST
Suspected part:
1. Remove the AC power to the system, wait 20 seconds,
and reconnect the AC power. Wait 30 seconds and
power on the system.
2. Flash update the service processor.
3. System board
4. Processor/PCI board
1762
Hard-disk-drive configuration
error
1. Run Configuration/Setup
2. Hard disk cables
3. Hard disk adapter
4. Hard disk drive
5. SCSI backplane
6. System board
178X
Hard-disk-drive error
1. Run diagnostics
2. Hard disk cables
3. Hard disk adapter
4. Hard disk drive
5. System board
1800
No more hardware interrupts
available for PCI adapter
1. Run Configuration/Setup
2. Failing adapter
3. System board
1962
Drive does not contain a
valid boot sector
1. Verify that a bootable operating system is installed.
2. Run diagnostics
3. Hard disk drive
4. SCSI backplane
5. Cable
6. System board
5962
IDE CD-ROM configuration
error
1. Run Configuration/Setup
2. CD-ROM drive
3. CD-ROM power cable
4. IDE Cable
5. System board
6. Battery
8603
Pointing-device error
1. Pointing device
2. System board
Appendix C. Engine POST messages