beautypg.com

IBM 201 User Manual

Page 107

background image

Table 17. POST error messages (continued)

Error
code/Symptom

Meaning

FRU/action

1600

The Service Processor is not
functioning

1. Ensure that a jumper is not installed on J-51

2. Remove the AC power to the system, wait 20 seconds

and then reconnect the AC power. Wait 30 seconds; then,
power-on the appliance.

3. System board

4. Processor/PCI board

1601

The system is able to
communicate to the Service
Processor, but the Service
Processor failed to respond
at the start of POST

Suspected part:

1. Remove the AC power to the system, wait 20 seconds,

and reconnect the AC power. Wait 30 seconds and
power on the system.

2. Flash update the service processor.

3. System board

4. Processor/PCI board

1762

Hard-disk-drive configuration
error

1. Run Configuration/Setup

2. Hard disk cables

3. Hard disk adapter

4. Hard disk drive

5. SCSI backplane

6. System board

178X

Hard-disk-drive error

1. Run diagnostics

2. Hard disk cables

3. Hard disk adapter

4. Hard disk drive

5. System board

1800

No more hardware interrupts
available for PCI adapter

1. Run Configuration/Setup

2. Failing adapter

3. System board

1962

Drive does not contain a
valid boot sector

1. Verify that a bootable operating system is installed.

2. Run diagnostics

3. Hard disk drive

4. SCSI backplane

5. Cable

6. System board

5962

IDE CD-ROM configuration
error

1. Run Configuration/Setup

2. CD-ROM drive

3. CD-ROM power cable

4. IDE Cable

5. System board

6. Battery

8603

Pointing-device error

1. Pointing device

2. System board

Appendix C. Engine POST messages

95