Table 17. POST error messages (continued)

Error
code/Symptom

Meaning

FRU/action

176

Computer cover or cable
cover was removed without a
key being used

1. Run Configuration/Setup

2. System board

3. C2 Security Switch

177, 178

Security hardware error

1. Run Configuration/Setup

2. System board

184

Power-on password
corrupted

1. Run Configuration/Setup

2. System board

185

Drive startup-sequence
information corrupted

1. Run Configuration/Setup

2. System board

186

Security hardware-control
logic failed

1. Run Configuration/Setup

2. System board

187

VPD serial number not set

1. Set serial number in Setup

2. System board

188

Bad EEPROM CRC #2

1. Run Configuration/Setup

2. System board

189

An attempt was made to
access the appliance with
invalid passwords

Run Configuration/Setup, enter the administrator
password

201

Memory test error

If the appliance does not have the latest level of BIOS
installed, update the BIOS to the latest level and run the
diagnostic program again.

1. DIMM

2. System board

229

Cache error

1. Run Configuration/Setup

2. Processor

3. Second Processor

262

DRAM parity configuration
error

1. Battery

2. System board

289

DIMM has been disabled by
the user or system

1. Run Configuration/Setup, if disabled by user

2. Disable DIMM, if not disabled by user

301

Keyboard or
keyboard-controller error

1. Keyboard

2. System board

303

Keyboard controller error

1. System board

2. Keyboard

602

Invalid diskette boot record

1. Diskette

2. Diskette drive

3. Cable

4. System board

Appendix C. Engine POST messages