IBM 201 User Manual
Page 105
Table 17. POST error messages (continued)
Error
code/Symptom
Meaning
FRU/action
176
Computer cover or cable
cover was removed without a
key being used
1. Run Configuration/Setup
2. System board
3. C2 Security Switch
177, 178
Security hardware error
1. Run Configuration/Setup
2. System board
184
Power-on password
corrupted
1. Run Configuration/Setup
2. System board
185
Drive startup-sequence
information corrupted
1. Run Configuration/Setup
2. System board
186
Security hardware-control
logic failed
1. Run Configuration/Setup
2. System board
187
VPD serial number not set
1. Set serial number in Setup
2. System board
188
Bad EEPROM CRC #2
1. Run Configuration/Setup
2. System board
189
An attempt was made to
access the appliance with
invalid passwords
Run Configuration/Setup, enter the administrator
password
201
Memory test error
If the appliance does not have the latest level of BIOS
installed, update the BIOS to the latest level and run the
diagnostic program again.
1. DIMM
2. System board
229
Cache error
1. Run Configuration/Setup
2. Processor
3. Second Processor
262
DRAM parity configuration
error
1. Battery
2. System board
289
DIMM has been disabled by
the user or system
1. Run Configuration/Setup, if disabled by user
2. Disable DIMM, if not disabled by user
301
Keyboard or
keyboard-controller error
1. Keyboard
2. System board
303
Keyboard controller error
1. System board
2. Keyboard
602
Invalid diskette boot record
1. Diskette
2. Diskette drive
3. Cable
4. System board
Appendix C. Engine POST messages
93