Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

166-342-000

System Management failed:
Remote Supervisor Adapter
BIST indicate failed tests).

1. Ensure that the latest firmware levels for the Remote

Supervisor Adapter and BIOS

2. Disconnect all server and option power cords from the

unit, wait 30 seconds, reconnect, then retry.

3. Remote Supervisor Adapter

166-400-000

System Management failed:
System management
hardware on system board
failed) (ISMP Self Test Result
failed tests: x where x =
Flash, RAM, or ROM).

1. Re-flash or update firmware for ISMP

2. System board

180-XXX-000

Diagnostics LED failure

Run the diagnostics LED test for the failing LED.

180-XXX-001

Failed front LED panel test

180-XXX-002

Failed diagnostics LED panel
test

1. System board

2. Power-switch assembly

180-XXX-005

Failed SCSI backplane LED
test

1. SCSI backplane

2. SCSI backplane cable

3. System board

180-XXX-006

Memory Board LED test

Suspected part:

1. Memory

2. Processor/PCI board

3. System board

180-361-003

Failed fan LED test

1. Fans

2. System board

201-XXX-0NN

Failed Memory test

1. DIMM Location DIMM1 - DIMM4 where NN can be a

value from 01 to 04. 01 = DIMM2, 02 = DIMM1, 03 =
DIMM4, 04 = DIMM3

2. System board

201-XXX-999

Multiple DIMM failure; see
error text for failing DIMMs

1. See error text for failing DIMMs

2. System board

202-XXX-001

Failed system cache test

1. VRM 1

2. Microprocessor 1

202-XXX-002

Failed system cache test

1. VRM 2

2. Microprocessor 2

206-XXX-000

Failed diskette drive test

1. Cable

2. Diskette drive

3. System board

215-XXX-000

Failed IDE CD-ROM test

1. CD-ROM drive cables

2. CD-ROM drive

3. System board

217-198-XXX

Could not establish drive
parameter

1. Check cable and termination

2. SCSI backplane

3. Fixed disk

Appendix C. Engine POST messages

103