beautypg.com

IBM 201 User Manual

Page 114

background image

Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

166-198-000

System Management
aborted: (Unable to
communicate with the
Remote Supervisor Adapter.
It may be busy. Run the test
again). (Communication with
the Remote Supervisor
Adapter has failed).

1. Re-run the Diagnostic Test

2. Fix other error conditions and retry. These include other

Failed System Management tests and items logged in the
optional Remote Supervisor Adapter’s System Error Log

3. Disconnect all server and option power cords from the

unit, wait 30 seconds, reconnect, and retry.

4. Remote Supervisor Adapter, if installed

5. System board

166-201-001

System Management failed:
(I2C Bus Error(s))

(ISMP indicates I2C errors on
bus 0. Potential FRUs:
Memory DIMMs, system
board)

1. If installed, reseat I2C cable between Remote

Supervisor Adapter (in PCI slot 1/J44) and system
board

2. Reseat memory DIMMs

3. Memory DIMMS

4. System board

166-201-002

System Management failed:
(I2C Bus Error(s))

(ISMP indicates I2C errors on
bus 2. Potential FRUs: LED
front panel, system board).

1. Reseat I2C cable between operator information panel

and system board (J39)

2. Operator information panel

3. System board

166-201-003

System Management failed:
(I2C Bus Error(s))

(ISMP indicates I2C errors on
bus 3. Potential FRUs: power
backplane, system board).

1. Reseat cables between power backplane and system

board

2. Operator information panel

3. System board

166-201-004

System Management failed:
(I2C Bus Error(s))

(ISMP indicates I2C errors on
bus 4. Potential FRUs: DASD
backplane, system board).

1. If installed, reseat I2C cable between Yugo and DASD

backplane and DASD I2C on system board (J0)

2. System board

166-201-005

System Management failed:
(I2C Bus Error(s))

(ISMP indicates I2C errors on
bus 0, 1, or 5. Potential
FRUs: Memory DIMMs,
CPUs, system board).

1. Reseat Memory DIMMs

2. Reseat processors

3. Memory DIMMs

4. Processors

5. System board

166-260-000

System Management failed:
(Unable to restart Remote
Supervisor Adapter). Restart
Remote Supervisor Adapter
Error. After restarting,
Remote Supervisor Adapter
communication was lost.
Unplug and cold boot to reset
the Remote Supervisor
Adapter).

1. Disconnect all server and option power cords from

server, wait 30 seconds, reconnect, and retry.

2. Reseat the Remote Supervisor Adapter in PCI slot 1/J44).

3. Remote Supervisor Adapter

102

NAS 200 User’s Reference