Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

014-XXX-000

Failed Parallel Port test

System board

015-XXX-001

Failed USB test

System board

015-XXX-015

Failed USB external loopback
test

1. Make sure parallel port is not disabled

2. Re-run USB external loopback test

3. System board

015-XXX-198

USB device connected
during the USB test

1. Remove USB devices from USB1 and USB2

2. Re-run USB external loopback test

3. System board

020-XXX-000

Failed PCI Interface test

System board

020-XXX-001

Failed Hot-Swap Slot 1 PCI
Latch test.

1. PCI hot-swap latch assembly

2. System board

020-XXX-002

Failed hot-swap slot 2 PCI
latch test

1. PCI hot-swap latch assembly

2. System board

020-XXX-003

Failed hot-swap slot 3 PCI
latch test

1. PCI hot-swap latch assembly

2. System board

020-XXX-004

Failed hot-swap slot 4 PCI
latch test

1. PCI hot-swap latch assembly

2. System board

030-XXX-000

Failed internal SCSI interface
test

System board

035-XXX-099

No adapters were found

If the adapter is installed, recheck the connection.

035-XXX-S99

Failed RAID test on PCI slot
S

Note: Check the System Error Log before replacing a part.

1. Adapter

2. SCSI backplane

3. Cable

035-XXX-SNN

NN = SCSI ID of failing hard
disk

Note: Check the System Error Log before replacing a
part.Hard disk drive with SCSI ID NN on RAID adapter in
PCI slot
S.

035-253-S99

RAID adapter initialization
failure; ServeRAID Adapter in
slot S is not configured
properly

1. Obtain the basic and extended configuration status

and refer to the ServeRAID Hardware Maintenance
Manual
for more information

2. Adapter

3. SCSI backplane

4. Cable

075-XXX-000

Failed power supply test

Power supply

089-XXX-001

Failed microprocessor test

1. VRM 1 for microprocessor 1

2. Microprocessor 1

089-XXX-002

Failed test for optional
microprocessor

1. VRM 2

2.

Optional microprocessor 2

166-250-000

System Management failed:
(I2C cable is disconnected.
Reconnect I2C cable
between Remote Supervisor
Adapter and system board.)

1. Reseat the I2C cables between Remote Supervisor

Adapter (in PCI slot 1/J44) and system board (J45)

2. I2C cables

Appendix C. Engine POST messages

101