Intel SERVER BOARD SDS2 User Manual
Page 78

BIOS
Intel® Server Board SDS2
Revision 1.2
Order Number: A85874-002
64
Feature
Option
Description
Assert NMI on PERR
Disabled
Enabled
If enabled, PCI bus parity error (PERR) is
enabled and is routed to NMI.
Assert NMI on SERR
Enabled
Disabled
If enabled, PCI bus system error (SERR) is
enabled and is routed to NMI.
FRB-2 Policy
FRB2 Disable
Disable Immediately
Never Disable
Allow 3 Failures
Controls the policy of the FRB-2 timeout. This
option determines when the Boot Strap
Processor (BSP) should be disabled if FRB-2
error occur. And Detemines when FRB2 stop.
Thermal Sensor
Disabled
Enabled
Determines wheter Thermal Sensor monitoring
function
BMC IRQ
IRQ11
IRQ5
IRQ10
Disabled
Determines BMC IRQ.
Post Error Pause
Disabled
Enabled
If enabled, the boot is stopped when Post error
occurs.
AC Link
Power On
Last State
Stay off
Selects system p ower state after AC loss.
Table 46. System Management Submenu Selections
Feature
Option
Description
BIOS Version
Information field only
Board Part Number
Information field only
Board Serial Number
Information field only
Sys tem Part Number
Information field only
System Serial Number
Information field only
Chassis Part Number
Information field only
Chassis Serial Number
Information field only
BMC Device ID
Information field only.
BMC Device Revision
Information field only.
BMC Firmware Revision
Information field only.
BMC Firmware BootBlock Revision
Information field only.
BMC Support IPMI Version
Information field only.
SDR Revision
Information field only.
PIA Revision
Information field only.
Primary HSBP Revision
Information field only, hidden if not detected
Secondary HSBP Revision
Information field only, hidden if not detected