Intel SERVER BOARD SDS2 User Manual
Page 59
Intel® Server Board SDS2
BIOS
Revision 1.2
Order Number: A85874-002
45
6.2.5
Error Messages and Error Codes
The system BIOS displays error messages on the video screen. Before video initialization, beep
codes inform the user of errors. POST error codes are logged in the System Event Log. The
BIOS displays POST error codes on the video monitor.
6.2.5.1
ASF Progress Codes
The BIOS utilizes ASF Progress Events as described in the ASF Specification, Revision 1.0a
from the DMTF. The events that the BIOS supports are shown in the following table.
Table 25. Event Request Message Event Data Field Contents
ASF Code
Description
Comment
01h
Memory initialization.
At beginning of ECC initialization or memory test.
02h
Hard-disk initialization
At beginning of IDE device detection.
03h
Secondary processor(s) initialization
At beginning of MP Init
04h
User authentication
When waiting for User/Supervisor password
05h
User-initiated system setup
When Setup is invoked
06h
USB resource configuration
When USB devices scan/initialization begins
07h
PCI resource configuration
At beginning of configuring PCI devices in system.
08h
Option ROM initialization
At beginning of Option ROM scan
09h
Video initialization
At beginning of initialization primary video controller (if
present)
0Ah
Cache initialization
At beginning of setting up processor cache
0Bh
SM Bus initialization
At beginning of configuring SMBus to communicate
with BMC
0Ch
Keyboard controller initialization
At keyboard discovery scan
0Dh
Embedded controller/management
controller initialization
When first checking for functional BMC
12h
Calling operating system wake-up
vector
When waking from Wake-On-LAN, Wake-On-Ring,
Magic Packet, etc.
13h
Starting operating system boot
process, e.g. calling Int 19h
Immediately prior to calling INT19h
6.2.5.2
POST Codes
The BIOS indicates the current testing phase to I/O location 80h and to LCD on the front panel
during POST after the video adapter has been successfully initialized. If a Port-80h card
(Postcard*) is installed, it displays this 2-digit code on a pair of hex display LEDs.
Table 26. Port-80h Code Definition
Code
Meaning
CP
Phoenix* check point POST code