Measurements from diagnostics, Firmware upgrades, Figure 24: system upgrade window – Motorola T1/E1 User Manual
Page 59: Table 13: comparison of diagnostic measurements, Procedure 29: upgrading firmware
Canopy T1/E1 Multiplexer
September 2004
T1/E1 Multiplexer FPGA Version 3.4
Page 59 of 73
3.5 MEASUREMENTS FROM DIAGNOSTICS
A unit-based comparison of diagnostic measurements is provided in
Table 13: Comparison of diagnostic measurements
Measurement Description Availability
Advantage
Disadvantage
Bit errors
Logic errors in
the bit stream
Only out of
service
Best unit for
point-to-point
performance
Requires that all traffic
be test traffic (known
data pattern)
BPVs
Pulses of the
same consecutive
polarity
In service
or out of
service
Good for circuit
or repeater
problems
Meaningful for only
metallic media, because
some equipment corrects
BPVs
Frame errors
Incorrect values
in the framing
bit position
In service
or out of
service
Approximates
bit error rate on
in-service basis
Evaluates only overhead
bits
CRC errors
Bit errors in a
block of data
In service
or out of
service
98.4% bit error
rate accuracy
Available with only ESF
framing
3.6 FIRMWARE UPGRADES
Firmware upgrades are periodically made available to enhance performance or to add
features and functionality to the Canopy T1/E1 Multiplexer.
Procedure 29: Upgrading firmware
To install new firmware on a Canopy T1/E1 Multiplexer, perform the following steps.
1. Close any other applications that are active on the PC.
2. From the main menu of the EMS, select Config
→Software Upgrade (shown in
RESULT: The System Upgrade window opens, as shown in
Figure 24: System Upgrade window