2.4.4 Select Line Coding
Procedure 9: Configuring line coding using the CLI
Follow this procedure to select the appropriate line code using the CLI manager.
Action Steps
Log in
Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
Set line code
Enter set line [1/2/3/4] code [HDB3/B8ZS/AMI]
where
HDB3
sets the line type to HDB3 for all 4 E1 ports
B8ZS
sets the line type to B8ZS for all 4 T1 ports.
AMI
sets the line type to AMI for all 4 E1 or T1 ports.
RESULT: The system selects the line code for all four ports, as in the
following example.
Line code [1/2/3/4] set to [HDB3/B8ZS/AMI]
Get line code
Enter get line code.
RESULT: The system returns the line code for all four ports, as in the
following example.
Line code [1/2/3/4] set to [HDB3/B8ZS/AMI]
end of procedure