beautypg.com

Accessing the cli using a pc + hyperterminal, Procedure 6: configuring serial port – Motorola T1/E1 User Manual

Page 34

background image

Canopy  T1/E1 Multiplexer 

 

 

 

 

 

 

September 2004 

 

 

 

 

 

 

     

      T1/E1 Multiplexer FPGA Version 3.4 


Page 34 of 73 

2.3.3 Accessing the CLI using a PC + HyperTerminal  

The Command Line Interface (CLI) is accessed using a PC with that includes a terminal
emulation package such as HyperTerminal

®

.

NOTE: The device is only accessible through the serial port.

2.3.4 Configuring the Canopy T1/E1 Multiplexer using the CLI 

Before you use the CLI to configure the Canopy T1/E1 Multiplexer, you must configure
the PC serial port.

Procedure 6: Configuring serial port

Use this procedure to access the CLI using a terminal emulation program such as
HyperTerminal.

®

1. Connect the serial cable from the DB9 serial port on a PC to the Serial port on

the Canopy T1/E1 Multiplexer. The DB9 connector on Canopy T1/E1 Multiplexer
is female; the cable from the PC is male. A straight-through cable is required.

2. Start HyperTerminal or another terminal emulation program.

3. Set the terminal emulation program to emulate a VT100 terminal with the

following settings:

Parameter Value

Bits per second

19200

Data bits

8

Parity none

Stop bits

1

Flow control

none

4. Press

Enter.

The Canopy T1/E1 Multiplexer Login menu is displayed.
RESULT: The signal port is configured.

end of procedure

To use the CLI, select Command Line Interface terminal from the File drop-down menu
(illustrated in

Figure 14

on Page

33

). The Command Line Interface window opens, as

shown in

Figure 16

.

Issue 3