Canopy  T1/E1 Multiplexer 

 

 

 

 

 

 

September 2004 

 

 

 

 

 

 

     

      T1/E1 Multiplexer FPGA Version 3.4 


Page 40 of 73 

Procedure 11: Configuring the T1 ports using the CLI

Follow this procedure to configure the T1 ports from the CLI manager.

Action Steps

Log in

Press Enter.

At the username prompt, enter admin.

At the password prompt, enter password.

Set T1 line length

NOTE: If the incorrect line length is selected, the result could be decreased
T1 quality or echo on voice lines. The default length is 133 ft.

Enter

set line [1/2/3/4] length [133, 266, 399, 533]

where
[1/2/3/4]

represents T1 ports 1 through 4.

[133, 266, 399, 533, 655]

represents line length in feet.

RESULT: The system responds

Line [1/2/3/4] length [0-133 / 0.6 dB; 133-266 / 1.2
dB; 266-399 / 1.8 dB; 399-533 / 2.4 dB; 533-655 / 3.0
dB]

Set T1 line code

NOTE: If the line code does not match the incoming T1 settings, then Bipolar
Violations (BPVs) will occur. The default code is B8ZS.

Enter set line [1/2/3/4] code [B8ZS/AMI]

where

[1/2/3/4]

represents T1 ports 1 through 4.

[B8ZS/AMI]

represents the line coding scheme.

RESULT: The system responds

Line [1/2/3/4] code [B8ZS/AMI]