2 INSTALLING AND CONFIGURING YOUR CANOPY
T1/E1 MULTIPLEXERS
2.1 SAFETY INFORMATION
2.1.1 Compliance
It is the responsibility of the installer to be sure that all building and safety codes are met
and that the installation is complete and secure.
For Canadian installations, the entire equipment installation must comply with Canadian
Standard CSA 22.2, No. 60950, Safety of Information Technology Equipment. For
installations in the United States, the entire equipment installation must be in accordance
with Article 810 of the United States National Electrical Code.
2.1.2 Lightning Protection
When installed, this equipment is to be connected to a Lightning/Surge Protection Device
that meets all applicable national safety requirements. See
2.1.3 Electrocution Hazard
WARNING!
Electrocution Hazard
This product is intended to be connected to either a 3.3-v DC power source (supplied by
Canopy) or an external
−48 v DC supply, which must be electrically isolated from any AC
sources and reliably connected to ground (Protective Earth). Do not install Canopy
products near any type of power line. If any related hardware contacts a power line,
severe bodily harm or death could result!
2.1.4 Power Supply Unit
WARNING!
An external AC surge suppression device must be used with the Canopy
T1/E1 Multiplexer. For infrastructure installations, Canopy Engineering
recommends an AC line surge suppression unit that meets the standard
IEC 801-5 (EN61000-4-5) Maximum Surge Voltage (1.2x50µsec) 6 KV.