2.4.6 Configure Timing 

Before the timing may be configured, you need to determine the network timing scheme
to be used. You also need to identify the master and slave devices for the end-user PBX
equipment.

Procedure 13: Configuring timing using the CLI

Action Steps

Log in

Press Enter.

At the username prompt, enter admin.

At the password prompt, enter password.

Set master clock
reference line

NOTE: This is the master clock reference for all four T1/E1 lines.
The default setting is T1/E1 Port 1.

Enter set master clock reference line [1/2/3/4]

where

[1/2/3/4]

represents T1/E1 ports 1 through 4.

RESULT: The system responds

Clk ref line; [1,2,3,4]

Set backup clock
reference line

NOTE: This is the optional backup clock reference for all four T1/E1 lines. The
backup clock reference becomes active only when the master clock reference
line is unavailable. The default setting is T1/E1 Port 2.

Enter set secondary clock reference line [1/2/3/4]

where

[1/2/3/4]

represents T1/E1 ports 1 through 4.

RESULT: The system responds

Backup clk ref line; [1/2/3/4]