User guide – Multi-Tech Systems MT5634ZBAV User Manual
Page 70

User Guide
60
Command:
&Zy
=x Store Dialing Command
Values:
y = 0–3 (callback security disabled) or 0–29
(callback security enabled)
x = Dialing command
Default:
None
Description:
Stores dialing command
x in memory location y.
Dial the stored number using the command
ATDS=y. See also the
#CBSn command. For
callback security options, see Chapter 6.
Command:
&&S
Speaker Codec Loopback
Values:
n/a
Description:
Provides a loopback from the microphone to the
speaker.
For testing and debugging only.
Command:
\A
n
Select Maximum MNP Block Size
Values:
n = 0, 1, 2, or 3
Default:
3
Description:
\A0
64-character maximum.
\A1
128-character maximum.
\A2
192-character maximum.
\A3
256-character maximum.
Command:
\B
n
Transmit Break
Values:
n = 0–9 in 100 ms units
Default:
3
Description:
In non-error-correction mode only, sends a break
signal of the specified length to a remote modem.
Works in conjunction with the
\K command.