Australian modem warning notice, Modem commands, Call attempts/retries – Multi-Tech Systems MT5634ZBAV User Manual
Page 131: Modem commands call attempts/retries, A regulatory compliance

A Regulatory Compliance
121
Australian Modem Warning Notice
Modems connected to the Australian telecommunications network must
have a valid AUSTEL permit. This modem has been specifically config-
ured to ensure compliance with AUSTEL Standards. The following
commands can affect compliance and must not be set outside the per-
missible range.
Modem Commands
Command
Default
Permissible Range
A:
Do not use
—
ATB
B0
Do not change
AT&G
&G2
Do not change
AT&P
&P1
Do not change
ATSn
see table below —
S-Register Default
Permissible Range
S6
4
2–5
Call Attempts/Retries
Applications software shall be configured so that no more than 3 at-
tempts are made to establish a connection to a given number. (Note: if
the modem can detect service tones, up to 10 attempts can be made).
There must be at least 2 seconds between call attempts. If the call se-
quence is unsuccessful, there shall be a delay of at least 30 minutes
before attempting to call the number again.