10/100 ethernet interface card removal procedure, 10/100 ethernet interface card – McDATA ULTRANETTM EDGE STORAGE ROUTER 3000 User Manual
Page 289
12
Hardware Maintenance
12-11
10/100 Ethernet Interface Card Removal Procedure
For I/O 1, the Fibre Channel interface card will plug into location
J14 and J15 on the motherboard. If the Fibre Channel interface
card is being installed into I/O 2, plug it into location J12 and J13
on the motherboard.
2. Secure the Fibre Channel interface card using the two screws that
were made available during the removal procedure. Torque to 6
in-lbs
.
3. Reconnect the power cords (rear).
4. Turn on the power supplies.
5. Replace the cover by following the Top Cover Installation
Procedure.
NOTE:
To replace the Fibre Channel transceiver, see the replacement
procedures found later in this chapter.
10/100 Ethernet Interface Card Removal Procedure
Use the following procedure to remove the 10/100 Ethernet interface
card from the UltraNet Edge 3000.
Tools required:
A small Phillips screwdriver and an adjustable
Torque driver, rated between 3 and 15 in-lbs.
CAUTION
Attach a wrist strap and follow ESD procedures (see page B-19)
during the handling of all electronic components.
1. Follow the Top Cover Removal Procedure.
2. Turn off both power supplies on the UltraNet Edge 3000.
3. Unplug the power cords.
4. Locate the 10/100 Ethernet interface card.
The 10/100 Ethernet interface card is located on the front left side
of the UltraNet Edge 3000 and can occupy I/O 3 and I/O 4 (see
illustration below).
5. Remove the two screws at the rear of the 10/100 Ethernet
interface card.