beautypg.com

Blue>request license key from technical support, Blue>power down the ultranet edge 3000 unit – McDATA ULTRANETTM EDGE STORAGE ROUTER 3000 User Manual

Page 269

background image

11

Product Support and Software Maintenance

11-7

Upgrading the UltraNet Edge 3000 Software

4. Replace the UltraNet Edge 3000 Chassis and Update UCM

5. FTP the New UltraNet Edge 3000 Software

6. Install the New UltraNet Edge 3000 Software

7. Deliver the Configurations

Request License Key

from Technical

Support

When an UltraNet Edge 3000 chassis is replaced, McDATA Technical
Support will need to create a License Key for the new hardware
replacement. The License Key is based on the serial number of the
new unit and feature functionality that was originally ordered with
the unit.

Obtain Current

Version of UltraNet

ConfigManager

Obtain the most current version of UltraNet ConfigManager (UCM)
from McDATA and install it on the Windows PC used to configure
the network.

Power Down the

UltraNet Edge 3000

Unit

Use the following procedure to power down the UltraNet Edge 3000:

1. Direct the on-site technician to power off the UltraNet Edge 3000

that is being replaced.

2. Direct the on-site technician to remove all cabling.

3. Direct the on-site technician to remove all applicable interface

cards.

4. Direct the on-site technician to remove the unit.

Replace the UltraNet

Edge 3000 Chassis

and Update UCM

Use the following procedure to replace the new UltraNet Edge 3000
chassis and update UCM:

1. Direct the on-site technician to replace the old unit with the new

UltraNet Edge 3000 chassis.

2. Direct the on-site technician to replace all cabling.

3. Direct the on-site technician to replace all applicable interface

cards.

4. Direct the on-site technician to power on the unit.

5. Using terminal emulation, dial into the new UltraNet Edge 3000.

6. Issue the

setNetCfg

command to configure the Ethernet

maintenance interface IP host address, default gateway, and
subnet mask.

7. Issue the

reset

command to reboot the UltraNet Edge 3000.