beautypg.com

Beginning assembly, Air line installation, Dust collection – Grizzly G0486/G0487 User Manual

Page 18

background image

-16-

G0486/G0487 Wide Belt Sander

To install the air line:

1. Connect the hose from your air compressor

to the air inlet (

Figure 11) on the regulator.

Air Inlet

Air ON/OFF

Lever

(Open Position)

Regulator

Knob

2. Make sure the red handle on the regulator

is in the open position (parallel with the air
inlet).

3. Lift the regulator knob (Figures 11

&

12)

and turn it until the air pressure gauge reads
75 PSI.

Note: Turn the knob clockwise to

increase the air pressure and counterclock-
wise to lower the air pressure.

4. Push the regulator knob down until it snaps.

Beginning Assembly

Complete the assembly in the order provided in
this manual. Then read the rest of the manual
before attempting any type of sanding operation.

Your safety is important! Please follow the

warnings below during this entire section:

Disconnect power to the

machine for the assem-

bly process. Failure to

do this may result in

serious personal injury.

Figure 11. Air inlet located on regulator.

Air Line Installation

Figure 12. Regulator knob.

Dust Collection

Figure 13. A typical screw configuration.

An efficient and clean dust collection system is
essential to the proper function of the sander.
Ensuring a healthy work environment is also
dependent upon cleaning and maintaining your
dust collection system. 4000 CFM is recom-
mended at the dust ports.

To hook up a dust collection system:

1. Install all ten dust ports (Figure 13) to the

mounting locations on the top of the sanding
unit with the supplied M6-1 x 10 Phillips head
screws.

2. Using 4" hose clamps, secure the hoses

from your dust collection system to the dust
ports.