Genicom GEK 00031B User Manual
Page 21
GEK-00029B
5000 Series Programmer’s Manual
21
CSI p1 p2 SP ~
GENEMU (Emulation Control): Switches the control of the printer to
another emulation. The parameters in the sequence are defined as
follows:
p1
Emulation identifier. This parameter selects the particular
emulation by a reference number supplied by GENICOM
engineering. The assigned numbers may be found in the table
below.
p2
Reset control. Permits the parameters of the printer to be
reset or defaulted. It is not always possible to meet the strict
definition of this parameter, so each printer has a definition of
how the reset control is implemented. The values as currently
defined are:
0
Hold values (default). All possible values for printer
control, e.g., tabs, margins, page length, are to be
retained.
1
Full reset. Resets parameters to initial state.
p1
Manufacturer
Emulation
0
GENICOM
ANSI
10
GENICOM
4410 ANSI
1-19
GENICOM
Reserved
20
IBM
Graphics Printer
21
IBM
Proprinter XL 9-wire
22
Epson
FX286-e
23
IBM
Proprinter XL 24-wire
24
Epson
LQ2500
30
Data Products
ANSI
40
Printronix
P300
41
Printronix
P5008
Indeterminate Conditions
If no emulation parameter is supplied, the emulation remains in the
current state and the rest of the sequence is ignored. Other
parameter values and other parameters are reserved.
Mnemonic:
Decimal:
27 91
Hex:
1B 5B
BASIC:
CHR$(27);"