GEK-00029A
5000 Series Programmer’s Manual
187
DECSTR
Soft Terminal Reset: Resets the value or state of several operating
features. After receiving a DECSTR, the printer positions itself at the
next Top Of Form then resets the value or state of several operating
features.
General Command Syntax
ESC [ ! p
Decimal:
27 71 17 84
Hex:
1B 5B 21 70
BASIC:
CHR$(27);"[";"!p";
Selectable Parameter
Reset Condition
Printing Status
On-line
Horizontal Pitch
10 characters per inch
Vertical Pitch
6 lines per inch
Font
Data Processing
Forms Length
66 lines (11 inches)
Active position
Column 1 on the current line
Top Margin
Line 1
Bottom Margin
Line 66
Left Margin
Column 1
Right Margin
Column 136
Underlining
Disabled
Bolding
Disabled
Italics
Disabled
Double Underline
Disabled
Overline
Disabled
Expansion
No character expansion
GL Character Set
US ASCII
GR Character Set
Digital Supplemental
G0
US ASCII
G1
VT100 Graphic Character Set
G2
Digital Supplemental
G3
US ASCII
Autowrap
Disabled
Line Feed/New Line Mode
Reset
Horizontal Tabs
Every 8 columns (9,17 …)
Unsolicited Reports
Disabled
Super/Subscripts
Disabled
Carriage Return/New line
Reset
Vertical Tabs
Every line (1-66)
NOTE
This sequence and the RIS reset sequence have the same
function.