Housekeeping sequences – Genicom GEK 00031B User Manual
Page 19

GEK-00029B
5000 Series Programmer’s Manual
19
Housekeeping Sequences
ESC [
CSI (Control Sequence Introducer): This sequence is used to begin
sequences, that generally have multiple parameters.
ESC ]
OSC (Operating System Command): This is another special
sequence introducer. Sequences which begin with OSC require the
ST string terminator sequence (ESC \) to end them.
ESC \
ST (String Terminator): Terminates the loading of EVFU tables,
download fonts, and dot graphics strings.
ESC c
RIS (Reset to Initial State): Resets the printer to either the standard
state shown below or to the state stored in the customer save area of
memory. The RIS sequence can be disabled by ANSI option strap 3
(see Appendix D, ANSI (4800) or ANSI (4410), option 3).
RIS – Reset to Initial State
Parameter
State
Font Style
Gothic Draft
Character Size
1X Vertical, 1X Horizontal
Character Pitch
10 cpi
Country Selection
USA
Code Page
437
Line Spacing
6 lpi
Partial Line Up
Reset
Partial Line Down
Reset
Bold Print
Inactive
Underline Mode
Inactive
Expanded Mode
Inactive
Proportional Mode
Reset
Horizontal Tab Table
Empty
Left Margin
None - Column 0
Right Margin
None - Maximum
Form Number
7
Page Size
7920 decipoints/ 66 lines/11 inches
Top Margin
None
Bottom Margin
None
Forms Position
Top of form - current position
Vertical Tab Table
Empty
Vertical Format Unit
Default
Graphics Density
60 H dpi, 72 V dpi, horizontal format
VFU Load In Progress
Exit (nothing saved)
Bar Code Mode
Inactive
Dot Graphics
Inactive
Decimal
27 99:
Hex:
1B 63
BASIC:
CHR$(27);"c";