CHAPTER 4: OPERATION

FUNCTIONALITY

MULTILINK ML1600 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL

4–5

The use of either multi-mode or single-mode fiber to operate at 100 Mbps speed over long
distances (i.e., in excess of 400 m) can be achieved only if the following are applied:

1.

The 100 Mb fiber segment must operate in full-duplex (FDX) mode (i.e. the full-
duplex (factory default).

2.

The worst-case OPB of the fiber link must be greater than the fiber cable's
passive attenuation, where attenuation is the sum of cable loss, LED aging
loss, insertion loss, and safety factor.

AG

100 Mb FX

single 18+ (0.4) km 1310 nm

9/125

μm

-20 dB

-31 dB

9.0 dB

18 km

12.5 dB

25 km

G3, G4, G5

1000 Mb

multi

0.55 km 1300 nm 62.5/125

μm

50/125

μm

-9.5 dB

-17 dB

5.5 dB

2 km

12.5 dB

4 km

GC

100 Mb FX

multi

2 (0.4) km 1310 nm 62.5/125

μm

50/125

μm

-20 dB-

23.5 dB

-31 dB

-31 dB

9.0 dB

5.5 dB

3.0 km

2.0 km

14 dB

12 dB

5.0 km

4.0 km

GF, GH, GJ

1000 Mb FX

single

10 km

1310 nm

9/125

μm

-9.5 dB

-20 dB

8.5 dB

17 km

10.5 dB

21 km

GK, GL, GM

1000 Mb FX

single

25 km

1310 nm

9/125

μm

-4.0 dB

-21 dB

15 dB

38 km

17.5 dB

43 km

Table 4–2: Power budget values for various modules

Module

Speed

Mode

fdx (hdx)

λ

Size

P

T

P

R

OPB

worst

d

worst

OPB

typ

d

typical