Document Outline
- Introduction
- Product Description
- 2.1 Overview
- 2.1.1 Four-port SFF fiber modules (CC Module, CD Module), 100Mb fiber
- 2.1.2 Four-Port Copper Module, C1 Module MDIX)
- 2.1.3 PoE (power pass-through), C2 Module (MDIX), 10/100Mb 4-port
- 2.1.4 Two-Port Fiber Modules, 2@ 100Mb fiber
- 2.1.5 Two -Port 10 Mb mm Fiber ST Modules
- 2.1.6 SFP Gigabit (1000Mbps) port modules
- 2.1.7 Packet Prioritization, 802.1p QOS
- 2.1.8 Frame Buffering and Flow Control
- 2.1.9 Managed Network Firmware for Multilink ML1200-Series
- 2.2 Features and Benefits
- 2.3 Applications
- 2.1 Overview
- Installation
- 3.1 Preparation
- 3.2 Connecting Ethernet Media
- 3.2.0.1 Connecting Fiber Optic ST-type, “twist-lock”
- 3.2.0.2 Connecting Fiber Optic SC-type, "Snap-In"
- 3.2.0.3 Connecting Single-Mode Fiber Optic
- 3.2.0.4 Connecting Twisted Pair (CAT3, CAT5, Unshielded or Shielded)
- 3.2.0.5 Connecting Twisted Pair (CAT5e or better, Unshielded or Shielded)
- 3.2.0.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers
- 3.2.0.7 Connecting Fiber Optic Cable to SFP Transceivers
- 3.3 Mechanical Installation
- 3.4 Electrical Installation
- Operation
- 4.1 Functionality
- 4.2 Multilink ML1200 Managed Field Switch Port Modules
- 4.2.1 Inspecting the Package and Product
- 4.2.2 ML1200 Modules
- 4.2.2.1 C8 Module, 2@100Mb multi-mode FX-ST “twist lock” Combo Module
- 4.2.2.2 C7 Module, 2@10Mb multi-mode FX-ST “twist lock” Module
- 4.2.2.3 C9 Module, 2@100Mb multi-mode FX-SC “snap-in” Fiber connector
- 4.2.2.4 CB Module, 2 Ports @100Mbps single-mode FX-SC-type, Sgl.M
- 4.2.2.5 C6 Module “COMBO” 2@ 10/100Mbps RJ-45 Ports and 1@100Mbps Multi-mode FX-SC-type, “snap-in” connector
- 4.2.2.6 CC Module, 4 @100Mb multi-mode FX , MTRJ Small-Form-factor
- 4.2.2.7 C3 Module, “COMBO” 2@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-FF
- 4.2.2.8 CD Module, 4 ports @ 100Mbps multi-mode LC connector SFF
- 4.2.2.9 C4 Module, Combo 2@ 100Mbps multi-mode -LC small-form factor and 2@ 10/ 100 Mbps RJ-45 Connector
- 4.2.2.10 C1 Module (Twisted Pair), 10/100Mb, 4-Port
- 4.2.2.11 PoE power-pass-through, Base unit Model ML1200-48P, 10/100Mb 4-port
- 4.2.2.12 SFPs, Gigabit (1000Mbps) port modules
- 4.2.2.13 Troubleshooting
- 4.2.3 Before Calling for Assistance
- IP Addressing
- Access Considerations
- Access Using RADIUS
- Access using TACACS+
- Port Mirroring and Setup
- VLAN
- VLAN Registration over GARP
- Spanning Tree Protocol (STP)
- Rapid Spanning Tree Protocol
- Quality of Service
- IGMP
- SNMP
- Miscellaneous commands
- Modbus Protocol
- Appendix A
- DC Power Input
- B.1 Specifications for Multilink ML1200 Switches, DC Power at 24 V and –48 V and 125 V DC Power input
- B.2 -48 V DC, 24 V DC and 125 V DC Power, Theory of Operation
- B.3 Applications for DC Powered Ethernet Switches
- B.4 ML1200, -48 V, 24 V, 125 V DC Installation
- B.5 UL Requirements for DC-powered units
- B.6 Operation
- Internal DC Dual-Source Power Input Option