Standard processing in SVP mode
IPL in PROGRAM LOAD FRAME: DETAIL-1
In this example, the PROGRAM LOAD FRAME: DETAIL-1 screen is displayed:
Figure 42: PROGRAM LOAD FRAME: DETAIL-1 screen
LOAD FUNCTION =>
Enter
3
for dialog startup.
IPL DEVICE =>
Enter
3
.
UNIT ADDRESS =>
Enter the device address of the load device.
In this example, the previous IPL was executed
successfully from the current device with device
address
A108
. Thus the desired address is already
in the
UNIT ADDRESS
field. It was also entered in the
CURRENT GROUP
field by the SVP. Entering a
2
in the
IPL DEVICE
field loads the operating system from
the desired device.
PARMS =>
Enter
1
in the first position of the field to load
VM2000.
MT CONTROL =>
1
is preset. This parameter is only important for
loading from tape.
----- PROGRAM LOAD FRAME: DETAIL-1 ----- E02L01F
-LOAD FUNCTION- -IPL DEVICE-
==> 3 ==> 3
*1 START AUTO *1 PRESET GROUP ------------------+
*2 START FAST >*2 CURRENT GROUP --------+ |
*3 START DIAL *3 UNIT ADDRESS -+ + +
*4 START A108 A108 0108
*5 SYSTEM DUMP XXXX XXXX
*6 LOAD CLEAR -----+ XXXX XXXX
*7 LOAD NON CLEAR -+ XXXX XXXX
|
+MT CONTROL- --- DETAIL-2 STATUS ---
PARMS=> 1 ==> 1 VM MODE : NATIVE
>*1 NL EXA MODE : ENABLE
*2 SL IPL EXEC : ENABLE
*3 NL-REWIND
*4 SL-REWIND *ENTER EXECUTE
*PF3 GO TO BASIC FRAME
*PF9 GO TO DETAIL-2
CL-0 CPU-0 CHP-0 RUN
M
FLAG CODE = F6C0C100 00000F00
LTG TAST