Ma) manual operation frame, 4 (ma) manual operation frame – Fujitsu Siemens Computers BS2000/OSD User Manual
Page 57
U25339-J-Z126-1-7600
57
Standard processing in SVP mode
User frames
6.4.4
(MA) MANUAL OPERATION FRAME
Figure 21: MANUAL OPERATION FRAME screen
By making an entry in this frame and pressing
, you can execute various manual
operations.
Instructions on this frame are only executed when the CPU has been stopped
(see message in frame line 23). The CPU status is displayed in line 22.
1. Selection of a CPU with the
key.
2. Stopping of the selected CPU (see (ML) MODE SELECTION FRAME page 47)
FUNCTION =>
The following functions are executed after the corresponding number
has been entered and the
key pressed:
1
RATE CONTROL
defines program operation
2
ADRS COMPARE STOP
sets mode for compare address stop
3
FIRMWARE DUMP
executes firmware dump
X
EXECUTE
executes functions 1 - 3
----- MANUAL OPERATION FRAME ----- E02L01F
FUNCTION=> ADDRESS COMPARE STOP
ADRS TYPE=>
*1 RATE CONTROL RATE CONTROL=> *1 ABSOLUTE
*1 PROCESS *2 LOGICAL
*2 ADRS COMPARE STOP *2 I-STEP
ADRS COMP SELECT=>
*3 FIRMWARE DUMP *1 ANY
*2 OPERAND FETCH(OFETCH)
*X EXECUTE *3 OPERAND STORE(OSTORE)
UNIT ADRS=> 0000 *4 INSTRUCTION ADRS(IA)
*5 IA & OFETCH
*6 OFETCH & OSTORE
ADRS SET=> XXXX
=> XXXXXXXX
ADRS COMP MODE=>
*1 RESET
*2 SET
*3 NORMAL
CL-0 CPU-0 CHP-0 RUN
M
FLAG CODE = F6C0C100 00000F00
LTG TAST
ENTER
P16
ENTER