beautypg.com

Ld) program load frame: detail-1 – Fujitsu Siemens Computers BS2000/OSD User Manual

Page 51

background image

U25339-J-Z126-1-7600

51

Standard processing in SVP mode

User frames

6.4.2.1

(LD) PROGRAM LOAD FRAME: DETAIL-1

Figure 17: PROGRAM LOAD FRAME: DETAIL-1 screen

By making entries in this screen and pressing the

key you can control the execution

of an IPL.

LOAD FUNCTION =>

The following functions are executed after the corresponding number
has been entered:

1

START AUTO

executes IPL: automatic startup

2

START FAST

executes IPL: fast startup

3

START DIAL

executes IPL: dialog startup

4

START

not used

5

SYSTEM DUMP

executes SLED

6

LOAD CLEAR

clears main memory before IPL

7

LOAD NON CLEAR

does not clear main memory before IPL

IPL DEVICE =>

By making an entry in this field you can specify from which device an
IPL is to be executed.

1

PRESET GROUP

The first device address in this column is the device
from which an IPL is to be executed. The order and
number has been specified previously in (AU5)
AUXILIARY FRAME: LOAD PRESET-1.

----- PROGRAM LOAD FRAME: DETAIL-1 ----- E02L01F

-LOAD FUNCTION- -IPL DEVICE-
==> ==> 2
*1 START AUTO *1 PRESET GROUP ------------------+
*2 START FAST >*2 CURRENT GROUP --------+ |
*3 START DIAL *3 UNIT ADDRESS -+ + +
*4 START FDE0 FDE0 0214
*5 SYSTEM DUMP XXXX 00B0
*6 LOAD CLEAR -----+ XXXX XXXX
*7 LOAD NON CLEAR -+ XXXX XXXX
|
+MT CONTROL- --- DETAIL-2 STATUS ---
PARMS=> 1 ==> 1 VM MODE : EMOS.AVM/EX
>*1 NL EXA MODE : ENABLE
*2 SL IPL EXEC : ENABLE
*3 NL-REWIND
*4 SL-REWIND *ENTER EXECUTE
*PF3 GO TO BASIC FRAME
*PF9 GO TO DETAIL-2

CL-0 CPU-0 CHP-0 RUN
M
FLAG CODE = F6C0C100 00000F00
LTG TAST

ENTER