beautypg.com

FUJITSU MHR2030AT User Manual

Page 99

background image

5.3 Host Commands

C141-E145-02EN

5-25

If an error occurs during multiple sector write operation, the write operation is
terminated at the sector where the error occurred. Command block registers
contain the cylinder, the head, the sector addresses (in the CHS mode) or the
logical block address (in the LBA mode) of the sector where the error occurred.

At command issuance (I/O registers setting contents)

1F7

H

(CM)

0

0

1

1

0

0

0

R

1F6

H

(DH)

x

L

x

DV

Start head No. / LBA
[MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(FR)

Start cylinder No. [MSB] / LBA

Start cylinder No. [LSB] / LBA

Start sector No. / LBA [LSB]

Transfer sector count

xx

At command completion (I/O registers contents to be read)

1F7

H

(ST)

Status information

1F6

H

(DH)

x

L

x

DV

End head No. / LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

End cylinder No. [MSB] / LBA

End cylinder No. [LSB] / LBA

End sector No. / LBA [LSB]

00 (*1)

Error information

*1

If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.

This manual is related to the following products: