beautypg.com

FUJITSU MHR2030AT User Manual

Page 26

background image

Device Overview

1-6

C141-E145-02EN

(3) Current Requirements and Power Dissipation

Table 1.3 lists the current and power dissipation (typical).

Table 1.3 Current and power dissipation

Typical RMS Current

Typical Power (*3)

MHR Series

MHR Series

Spin up (*1)

0.9 A

4.5 W

Idle

130 mA

0.65 W

R/W (on track) (*2)

460 mA

2.3 W

Seek (*5)

460 mA

2.3 W

Standby

50 mA

0.25 W

Sleep

20 mA

0.1 W

Energy
Efficiency (*4)

0.016 W/GB

(rank E / MHR2040AT)

0.016 W/GB

(rank E / MHR2030AT)

0.033 W/GB

(rank D / MHR2020AT)

0.033 W/GB

(rank D / MHR2010AT)

*1

Current at starting spindle motor.

*2

Current and power level when the operation (command) that accompanies a
transfer of 63 sectors is executed 3 times in 100 ms

*3

Power requirements reflect nominal values for +5V power.

*4

Energy efficiency based on the Law concerning the Rational Use of Energy
indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)

*5

The seek average current is specified based on three operations per 100
msec.

(4) Current fluctuation (Typ.) at +5V when power is turned on

This manual is related to the following products: