beautypg.com

FUJITSU MHR2030AT User Manual

Page 116

background image

Interface

5-42

C141-E145-02EN

Bit 0: '1' = Supports the Mode 0

*21 WORD 89

MHR2040AT = X'14': 40 minutes

MHR2020AT = X'0A': 20 minutes

*17 WORD 93

Bits 15:

= 0

Bit 14:

= '1'

Bit 13:

'1' = CBLID- is a higher level than VIH (80-conductor cable). It

is fixed at 1 in the MHR-series devices.

'0' = CBLID- is a lower level than VIL (40-conductor cable).

Bits 12-8: In the case of Device 1 (slave drive), a valid value is set.

Bit 12:

Reserved

Bit 11:

'1' = Device asserts PDIAG-.

Bit 10, 9: Method for deciding the device No. of Device 1.

'00' = Reserved

'01' = Using a jumper.

'10' = Using the CSEL signal.

'11' = Other method.

Bit 8:

= '1' (In the case of device 1)

Bits 7-0:

In the case of Device 0 (master drive), a valid value is set.

Bit 7:

Reserved

Bit 6:

'1' = Device 1 is selected, Device 0 responds.

Bit 5:

'1' = Device 0, assertion of DASP- was detected.

Bit 4:

'1' = Device 0, assertion of PDIAG- was detected.

Bit 3:

'1' = Device 0, an error was not detected in the self-

diagnosis.

Bit 2, 1:

Method for deciding the device No. of Device 0.

'00' = Reserved

'01' = Using a jumper.

'10' = Using the CSEL signal.

'11' = Other method.

This manual is related to the following products: