5.3 Host Commands

C141-E145-02EN

5-69

Table 5.7 Features Register values (subcommands) and functions (2 of 3)

Features Resister

Function

X’D5’

SMART Read Log Sector:

A device which receives this sub-command asserts the BSY bit, then reads
the log sector specified in the SN register. Next, it clears the BSY bit and
transmits the log sector to the host computer.

SN:

Log sector

00h:

SMART log directory

01h:

SMART summary error log

02h:

SMART comprehensive error log

06h:

SMART self test log

80h-9Fh: Host vendor log

*

See Table 5.11 concerning the SMART error log data format.
See Table 5.12 concerning the SMART self test log data format.

X’D6’

SMART Write Log Sector:

A device which receives this sub-command asserts the BSY bit and when it
has prepared to receive data from the host computer, it sets DRQ and clears
the BSY bit. Next, it receives data from the host computer and writes the
specified log sector in the SN register.

SN:

Log sector

80h-9Fh: Host vendor log

*

The host can write any desired data in the host vendor log.

X’D8’

SMART Enable Operations:

This subcommand enables the failure prediction feature. The setting is
maintained even when the device is turned off and then on.

When the device receives this subcommand, it asserts the BSY bit, enables
the failure prediction feature, then clears the BSY bit.

X’D9’

SMART Disable Operations:

This subcommand disables the failure prediction feature. The setting is
maintained even when the device is turned off and then on.

When the device receives this subcommand, it asserts the BSY bit, disables
the failure prediction feature, then clears the BSY bit.

This manual is related to the following products: