Fujitsu Siemens Computers SPARC Enterprise M8000 User Manual
Page 71

Chapter 3
DR User Interface
3-9
The following examples show displays of the showboards(8) command
■
Example 1
: Display of information on all system boards
Test
Diagnostic status of system board
Unmount
The system board is not mounted or cannot be
recognized because it is faulty.
Unknown
The system board is not being diagnosed.
Testing
testing.
Passed
The system board was tested, and passed.
Failed
A system board error was tested, and failed.
The system board cannot be used or has been
degraded.
Fault
Normal/abnormal status of system board
Normal
Normal.
Degraded
Components have been degraded, but the system
board is operating. Degraded here means that a
system board included in the corresponding
component is faulty
.
Failed
The system board cannot operate because of an error.
COD
Indication of whether the system board is a COD board.
n
The board is not a COD board.
y
The board is a COD board.
XSCF> showboards -a
XSB
DID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
------------------------------------------------------------------
00-0
00(00)
Assigned
y
y
y
Passed
Normal
00-1
00(01)
Assigned
y
n
n
Passed
Degraded
00-2
SP
Available
y
n
n
Unknown
Normal
00-3
01(15)
Assigned
y
y
y
Passed
Normal
TABLE 3-8
Items of System Board Information to be Displayed (Continued)
Display items
Description