A.2.6 showdevices, A.2.6, Showdevices – Fujitsu Siemens Computers SPARC Enterprise M8000 User Manual
Page 150: A–34
A-34
SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007
The specified parameter is not supported in this model.
[Explanation] Unsupported parameter in this server is specified. For this reason,
the command was canceled.
[Remedy] Confirm the specified parameter and the server model, and execute the
command once again.
Invalid parameter.
[Explanation] There is an error in the specified argument or operand.
[Remedy] Confirm the specified argument or operand and execute the command
once again.
Permission denied.
[Explanation] Do not have privilege.
[Remedy] Confirm the user privilege and the command privilege. In the case of
high-end servers, please also confirm whether command is executed by XSCF on
standby side.
The current configuration does not support this operation.
[Explanation] Cannot execute the command in the current configuration, or it is
not supported.
[Remedy] Confirm the current hardware configuration and support status.
An internal error has occurred. Please contact your system
administrator.
[Explanation] DR failed. There is a possibility that DR failed because of an
internal error in XSCF.
[Remedy] Find out the cause of the DR failure referring monitoring message and
error log. Please also confirm the XCP version.
A.2.6
showdevices
XSB#%s is not currently running.
[Explanation] The system was not able to get some parameter for the XSB.
[Remedy] Confirm the information for the XSB via the showboards command.
cannot get device information from DomainID.
[Explanation] The system was unable to collect the requested information from
the domain.