Fujitsu Siemens Computers SPARC Enterprise M8000 User Manual
Page 109

Chapter 4
Practical Examples of DR
4-19
9. Check the status of all related domains.
Execute the showdcl(8) command to display domain information, and then
check the operation status of all related domains. Based on the operation status of
the domain, determine whether to perform the DR operation or reboot the
domains.
10. Add the new system board to the domain.
Execute the addboard(8) command in the domain to add the new system board.
11. Check the status of the related domains and system boards.
Execute the showdcl(8) command to check the operation status of related
domains, and then execute the showboards(8) command to check the status of
related system boards.
In this example, domain #1 is booted by power-on in this stage.
XSCF> showdcl -a
DID
LSB
XSB
Status
00
Running
00
00-0
01
01-0
02
01-1
-------
01
Powered Off
00
01-2
01
01-3
XSCF> addboard -c configure -d 0 01-0 01-1
XSCF> poweron -d 1
XSCF> showdcl -a
DID
LSB
XSB
Status
00
Running
00
00-0
01
01-0
02
01-1
-------
01
Running
00
01-2
01
01-3