SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

[Explanation] DR fails to allocate enough memory to perform copy rename.

[Remedy] Retry and if the problem persists, contact customer service.

Failed to off-line: dr@0:SBX::cpuY

[Explanation] Failed to off-line CPU Y on board X.

[Remedy] Repeat the action. If this error message appears again, please contact
customer service.

[Output] Console and Standard Output

Failed to on-line: dr@0:SBX::cpuY

[Explanation] Failed to online CPU Y on system board X.

[Remedy] Online CPU with psradm -n. If it fails to online CPU, and if this
command fails again, respond in the manner directed by command message.

[Output] Console and Standard Output

Failed to start CPU: dr@0:SBX::cpuY

[Explanation] Failed to start CPU Y on system board X.

[Remedy] Please contact customer service.

[Output] Console and Standard Output

Failed to stop CPU: dr@0:SBX::cpuY

[Explanation] Failed to stop CPU Y on system board X.

[Remedy] Please contact customer service.

[Output] Console and Standard Output

Firmware deprobe failed: SBX::cpuY

[Explanation] Failed to deprobe the CPU.

[Remedy] Please contact customer service.

[Output] Console and Standard Output

Firmware probe failed: SBX

[Explanation] Failed to probe the board.

[Remedy] Respond in the manner directed by the other message.

[Output] Console and Standard Output

Insufficient memory: dr@0:SBX::memory