SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007
Operation already in progress: dr@0:SBX::cpuY
[Explanation] The operation on cpu Y on system board X is in progress.
[Remedy] Repeat the action. If the problem still exists, please contact customer
service.
[Output] Console and Standard Output
dr_move_memory: failed to quiesce OS for copy-rename
[Explanation] There is a task not suspended in the process.
[Remedy] Repeat the action. If this error message appears again, please contact
customer service.
[Output] Console and Standard Output
No available memory target: dr@0:SBX::memory
[Explanation] The system board cannot be detached because it contains kernel
memory and there is no available target memory board.
[Remedy] Add new system board and then try the detach operation again.
[Output] Console and Standard Output
Unsafe driver present:
[Explanation] DR driver found DR unsafe drivers in the system.
[Remedy] Unload the unsafe drivers and try the DR operation again.
[Output] Console and Standard Output
Device failed to resume:
[Explanation] Devices on the list failed to resume
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Device failed to suspend:
[Explanation] Devices on the list failed to suspend
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Operation not supported: ERROR
[Explanation] Invalid operation.
[Remedy] Repeat the action. If this error message appears again, please contact
customer service.