Chapter 4
Practical Examples of DR
4-17
3. Check the status of all related system boards.
Execute the showboards(8) command to display system board information, and
then check the status of all system boards related to the PSB to be replaced. The
DR operation for replacement may not be possible if the board to be replaced
does not support the DR delete operation.
4. Delete all system boards related to the CMU to be replaced.
Execute the deleteboard(8) command to delete the system boards, and then
assign the boards to a domain that permits the DR operation.
5. Power off Domain #1 so the CMU can be replaced.
Execute the poweroff(8) command so that the CMU being replaced will not be in
use by domain #1.
XSCF> showdcl -a
DID
LSB
XSB
Status
00
Running
00
00-0
01
01-0
02
01-1
-------
01
Running
00
01-2
01
01-3
XSCF> showboards -a
XSB
DID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
-----------------------------------------------------------------
00-0
00(00)
Assigned
y
y
y
Passed
Normal
01-0
00(01)
Assigned
y
y
y
Passed
Normal
01-1
00(02)
Assigned
y
y
y
Passed
Normal
01-2
01(00)
Assigned
y
y
y
Passed
Normal
01-3
01(01)
Assigned
y
y
y
Passed
Normal
XSCF> deleteboard -c disconnect 01-0 01-1
XSCF> poweroff -d 1