1 example: replacing a uni-xsb system board, Example: replacing a uni-xsb system board, Figure 4-8 – Fujitsu Siemens Computers SPARC Enterprise M8000 User Manual
Page 103
Chapter 4
Practical Examples of DR
4-13
4.5.1
Example: Replacing a Uni-XSB System Board
FIGURE 4-8
Example: Replacing a Uni-XSB System Board
1. Login to XSCF.
2. Check the status of the domain.
Execute the showdcl(8) command to display domain information, and then
check the operation status of the domain. Based on the operation status of the
domain, determine whether to perform the DR operation or replace the system
board after stopping the domain.
3. Check the status of the system board to be replaced.
Execute the showboards(8) command to display system board information, and
then check the status of the system board to be deleted. The DR operation for
replacement may not be possible if the board to be replaced does not support the
DR delete operation.
XSCF> showdcl -d 0
DID
LSB
XSB
Status
00
Running
00
00-0
01
01-0
XSCF> showboards 01-0
XSB
DID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
-----------------------------------------------------------------
01-0
00(01)
Assigned
y
y
y
Passed
Normal
Domain#0
XSB#00-0
XSB#01-0
Delete
Faulty
New
Replace
Add
system
board
system
board