beautypg.com

Leds – Fortinet FortiGate 5001A-SW User Manual

Page 7

background image

FortiGate-5001A security system

Front panel LEDs and connectors

FortiGate-5001A Security System Guide
01-30000-83456-20081023

7

LEDs

Table 1

lists and describes the FortiGate-5001A LEDs.

Table 1: FortiGate-5001A LEDs

LED

State

Description

1, 2
(Left LED)

Green

The correct cable is connected to the interface and the
connected equipment has power.

Flashing
Green

Network activity at the interface.

Off

No link is established.

1, 2
(Right LED)

Green

Connection at 1 Gbps.

Amber

Connection at 100 Mbps.

Off

Connection at 10 Mbps.

Base CH0

Green

Base backplane interface 0 (base1) is connected at 1 Gbps.

Flashing
Green

Network activity at base backplane interface 0.

Base CH1

Green

Base backplane interface 1 (base2) is connected at 1 Gbps.

Flashing
Green

Network activity at base backplane interface 1.

Fabric CH0

Off

Fabric backplane interface 0 (fabric1) is connected at 10
Gbps.

Flashing
Green

Network activity at fabric backplane interface 0.

Fabric CH1

Off

Fabric backplane interface 1 (fabric2) is connected at 10
Gbps.

Flashing
Green

Network activity at fabric backplane interface 1.

ACC

Off or
Flashing
green

The ACC LED flashes green when the FortiGate-5001A
board accesses the FortiOS flash disk. The FortiOS flash
disk stores the current FortiOS firmware build and
configuration files. The system accesses the flash disk when
starting up, during a firmware upgrade, or when an
administrator is using the CLI or GUI to change the FortiOS
configuration. Under normal operating conditions this LED
flashes occasionally, but is mostly off.

OOS
(Out of
Service)

Off

Normal operation.

Green

A fault condition exists and the FortiGate-5001A blade is out
of service (OOS). This LED may also flash very briefly during
normal startup.

Power

Green

The FortiGate-5001A board is powered on.

Status

Off

The FortiGate-5001A board is powered on.

Flashing
Green

The FortiGate-5001A is starting up. If this LED is flashing at
any time other than system startup, a fault condition may
exist.

IPM

Blue

The FortiGate-5001A is ready to be hot-swapped (removed
from the chassis). If the IPM light is blue and no other LEDs
are lit the FortiGate-5001A board has lost power.

Flashing
Blue

The FortiGate-5001A is changing from hot swap to running
mode or from running mode to hot swap. This happens when
the FortiGate-5001A board is starting up or shutting down.

Off

Normal operation. The FortiGate-5001A board is in contact
with the chassis backplane.

This manual is related to the following products: