Hardware installation

Inserting a FortiGate-5001A board

FortiGate-5001A Security System Guide
01-30000-83456-20081023

17

9

Turn both handles to their fully-closed positions.

The handles should hook into the sides of the chassis slot. Closing the handles
draws the FortiGate-5001A board into place in the chassis slot and into full
contact with the chassis backplane. The FortiGate-5001A front panel should be in
contact with the chassis front panel. For the FortiGate-5001A-DW, the right
(bottom) handle locks into place. For the FortiGate-5001A-SW, both handles lock
into place.

As the handles closed power is supplied to the board. If the chassis is powered on
the IPM LED starts flashing blue. If the board is aligned correctly, inserted all the
way into the slot, and the handles are properly closed the IPM LED flashes blue
for a few seconds. At the same time the STATUS LED flashes green, the interface
LEDs flash amber, and the ACC LED starts flashing green. After a few seconds
the IPM LED goes out and the FortiGate-5001A firmware starts up. During start
up the STATUS LED may continue to flash green. Once the board has started up
and is operating correctly, the front panel LEDs are lit as described in

Table 4

.

If you have installed an AMC module in the FortiGate-5001A board, the AMC
LEDs are lit as described in

Table 5

.

If the board has not been inserted properly the IPM LED changes to solid blue and
all other LEDS turn off. If this occurs, open the handles, slide the board part way
out, and repeat the insertion process.

Table 4: FortiGate-5001A normal operating LEDs

LED

State

ACC

Off (Or flashing green when the system accesses the
FortiGate-5001A flash disk.)

OOS
(Out of
Service)

Off

Power

Green

Status

Off

IPM

Off

Table 5: FortiGate AMC module normal operating LEDs

LED

State

HS

Off

OOS

Off

PWR

Amber

OT

Off